What happened

The Department for Energy Security and Net Zero (DESNZ) published its Boiler Upgrade Scheme statistics for October 2026 at 09:30 on 26 November 2026. The scheme gives a grant towards replacing fossil fuel heating with a heat pump or, in limited cases, a biomass boiler in England and Wales. A month after September set a record, which we reported in October, every measure rose again:

  • Applications: 14,286 in October, 47% more than September's 9,738 and 255% more than October 2025, the most in any month since the scheme began in 2022.
  • Vouchers issued: 8,221, also a monthly record.
  • Grants paid: a record 5,138, taking the total paid to 101,742, the first time it has passed 100,000.
  • Off-gas grant: since July, owners of properties off the gas grid heated by oil or LPG can get £9,000. That grant drew 12,016 applications from July to October, 30% of the 39,660 received in those four months.
  • What was replaced: 55% of all installations paid so far replaced gas heating, followed by oil (18%).

What it means for your business

Businesses are still barely using it. Of the 101,742 grants paid, 641 went to non-domestic properties,0.6%, up from 609 a month earlier. The scheme is open to small non-domestic buildings, so an owner-occupied shop, office or workshop may qualify; GOV.UK sets out the conditions, and the installer applies for you.

Demand is high and the budget is fixed. DESNZ says the scheme has £400 million for 2026/27 and vouchers are issued first come, first served until the year's budget is reached. With applications at a record, it is worth asking an installer early rather than late in the financial year.

A heat pump moves emissions between scopes. Gas burned on site is Scope 1 at 0.18231 kg CO2e per kWh; a heat pump runs on electricity, Scope 2 at 0.13096 on the 2026 government factors.

A worked example: an office on mains gas

Take an illustrative small office that burns 40,000 kWh of gas a year in a boiler about 90% efficient, so it gets about 36,000 kWh of heat. An air source heat pump with a seasonal efficiency of 3 gives the same heat from 12,000 kWh of electricity.

  • Gas boiler: 7.29 tonnes CO2e a year (Scope 1).
  • Heat pump: 1.57 tonnes CO2e a year (Scope 2).
  • That is about 78% less from heating, and the gap widens as the grid gets cleaner.

The inputs are illustrative. Real savings depend on the building, its insulation and the heat pump's actual performance, so use your own meter readings once it is running.

What to do now

  1. Check whether your building may qualify. Read the GOV.UK conditions and ask an MCS-certified installer for a survey.
  2. Record a year of gas or oil use first. Twelve months of kWh or litres gives you the baseline to size the heat pump and to show the saving afterwards.
  3. Report the switch properly. When the heat pump goes in, the gas line in Scope 1 falls and electricity in Scope 2 rises. Note the date, so the change is clear when you compare years.