What happened
BloombergNEF published "Powering the Data Center Boom: How Grid Policy Can Deliver Clean Power Faster" on 11 November 2026, a report commissioned by Bloomberg Philanthropies. It expects data centres to use about 2,354 TWh of electricity a year by 2035, almost four times today and about 7% of the world's electricity. Because grid connections in the US and Europe take years, developers are planning their own gas-fired power: BNEF has tracked 181 GW of gas generation to be built on site at data centres, 165 GW of it in the US, with small pockets in Canada, the UK and Ireland.
BNEF estimates that if every announced US on-site gas plant is built and runs at a 60% capacity factor, they would emit about 345 million tonnes CO2e a year. That is 152 million tonnes more than running the same data centres from the grid, equal to 10% of US power-sector emissions in 2025. It warns that plants meant as a five-to-seven-year "bridge" may keep running long after the grid arrives, locking in gas.
As Joshua Neil reported for edie on 13 November 2026, separate research from the insurance broker Howden finds US data centre electricity demand has grown by an average of 19% a year since 2000, against 2% a year for grid capacity, and that power constraints are adding two to six years to the worst-hit projects.
What the report says about the UK
BNEF compares the UK with France. France's government and its grid operator RTE have pre-identified 6 fast-track sites with 4.4 GW of reserved grid capacity, and four already have developers. The UK has named 5 AI Growth Zones, but BNEF says the way a data centre in a zone would get priority in the connection queue has yet to be decided, so the plan "has made less progress in energizing real projects".
On grid connections, BNEF reads Ofgem's proposed reforms (consulted on until September) as responding to a demand queue of 125 GW, of which data centres make up 73 GW. Entry to the queue stays fairly easy, but a data centre accepting a connection offer would post a security of £237,500 to £712,500 per MW and then meet delivery milestones to keep its place. BNEF says that is a much bigger fee than in Texas or Spain, and could deter genuine developers as well as speculative ones.
Our sums
Worked out with the same engine and the 2026 UK government electricity factor the app uses (0.13096 kg CO2e per kWh), with the 60% average load BNEF uses for the US plants:
- The whole GB data centre queue: 73 GW at 60% for a year is about 384 TWh, or about 50.2 million tonnes CO2e location-based. A lot of any connection queue is never built, which is exactly what Ofgem's security is meant to weed out, so read this as the size of the ask.
- One 100 MW site: about 526 GWh a year, or about 69 thousand tonnes CO2e from the grid. Under Ofgem's proposal it would post £23.75m to £71.25m of security on accepting its connection offer.
- Your own share: a business whose cloud and AI use comes to 20,000 kWh a year would report about 2,619 kg CO2e at the UK grid factor. If that work runs in a data centre on its own gas, the real figure is likely to be higher, because BNEF finds on-site gas more carbon-intensive than the grid where these plants are built.
These are location-based figures: under the GHG Protocol's Scope 2 rules, anything drawing from the grid reports the grid's average factor whatever its contract says. They are our estimates, not BNEF's, and the UK factor falls as the grid gets cleaner.
What it means for your business
Where your computing runs now matters to its carbon. A data centre on the grid carries the grid's factor; one waiting for a connection on its own gas turbines carries the gas plant's. Two providers selling the same service can have very different footprints.
The grid queue is shared. Data centres sit in the same queue as a factory wanting a bigger supply or a depot adding chargers. Ofgem's reforms aim to clear projects that will never be built, which could shorten the wait for everyone else.
Cloud is a growing Scope 3 line. Hosting, software and AI tools sit in category 1, purchased goods and services, and AI use is pushing the line up for many businesses.
What to do now
- Ask your cloud, hosting and AI providers two questions. How many kWh and how much CO2e sit behind your account, and is any of it powered by on-site generation rather than the grid? Our post on asking suppliers for carbon data has the wording.
- Report your own electricity both ways. Show location-based alongside market-based. Our UK electricity factor page has the location-based factor for each year.
- See where IT sits in your footprint. Our IT, cloud and laptop emissions guide covers each item.
- Read the UK picture. Our posts on four UK data centres considering gas, the Data Centre Covenant and the Edinburgh protest and the Chapelcross plan cover the power and planning questions here.