The numbers, year by year
Every June the Department for Energy Security and Net Zero (DESNZ) publishes conversion factors for company reporting. The UK electricity factor is the average emissions per kWh of electricity supplied to the grid, and it is what turns your kWh into location-based Scope 2. Here is every set from 2012, when the current method began (Carbon Recycling also holds the older sets back to 2002, which cover electricity and heat only):
| Factor set | Based on data for | Electricity, kg CO2e per kWh | Grid losses, kg per kWh | Natural gas, kg per kWh |
|---|---|---|---|---|
| 2012 | 2010 | 0.46002 | 0.03634 | 0.18521 |
| 2013 | 2011 | 0.44548 | 0.03809 | 0.18404 |
| 2014 | 2012 | 0.49426 | 0.04322 | 0.18497 |
| 2015 | 2013 | 0.46219 | 0.03816 | 0.18445 |
| 2016 | 2014 | 0.41205 | 0.03727 | 0.184 |
| 2017 | 2015 | 0.35156 | 0.03287 | 0.18416 |
| 2018 | 2016 | 0.28307 | 0.02413 | 0.18396 |
| 2019 | 2017 | 0.2556 | 0.0217 | 0.18385 |
| 2020 | 2018 | 0.23314 | 0.02005 | 0.18387 |
| 2021 | 2019 | 0.21233 | 0.01879 | 0.18316 |
| 2022 | 2020 | 0.19338 | 0.01769 | 0.18254 |
| 2023 | 2021 | 0.20707 | 0.01792 | 0.18293 |
| 2024 | 2022 | 0.20705 | 0.0183 | 0.1829 |
| 2025 | 2023 | 0.177 | 0.01853 | 0.18296 |
| 2026 | 2025 | 0.13096 | 0.01299 | 0.18231 |
Gas is there for comparison. Natural gas is chemically the same every year, so its factor barely moves. Electricity depends on how it was generated, so it changes a lot. From the 2025 set, a kWh of grid electricity has a lower factor than a kWh of gas burned in your own boiler, which changes the maths on electric heating and vehicles.
Why it keeps falling
The factor is, in simple terms, the emissions from UK power stations divided by the electricity they put on the grid, with an adjustment for imports through the interconnectors to France, Belgium, the Netherlands, Norway and Ireland. The DESNZ methodology paper shows power station CO2 roughly halving between the 2017 and 2025 data years, while the amount of electricity generated fell far less. Coal is a big part of the story: its use for power declined for a decade, and the last UK coal power station closed in September 2024.
DESNZ is clear that single years can still go the other way. The factor depends on the relative prices of coal and gas, peak demand and how much renewable generation there was that year. The 2014 set rose to 0.49426 from 0.44548, because it was built on 2012 data, a year when power station emissions went up.
Why the 2026 drop was so big
Until 2025, each set was built on data from two years earlier, because it relied on the national greenhouse gas inventory, which takes time to publish. For 2026, DESNZ switched to its quicker Energy Trends statistics and used 2025 data. The paper says this means no set is based on 2024 data. Two years of grid improvement arrived in one go, which is why the factor fell about 26% in a single year. Our post on why your footprint dropped in 2026 shows how to explain that in a report.
What it means for your footprint
An office uses the same 30,000 kWh of electricity every year:
- With the 2012 factor: 30,000 × 0.46002 = 13.80 tonnes CO2e
- With the 2026 factor: 30,000 × 0.13096 = 3.93 tonnes CO2e
Nothing changed in the office, yet reported Scope 2 fell by 9.87 tonnes. Three things follow:
- Separate the grid from your own work. Report the lower figure, but say how much came from the factor. Buyers reading a Carbon Reduction Plan know the grid is getting cleaner.
- Using less electricity still matters. Every kWh saved is real. It just saves fewer tonnes each year, so cutting gas and diesel often matters more now.
- Switching from fuel to electricity looks better every year. Heat pumps and electric vans benefit from each fall in the grid factor.
Grid losses (the middle column) are Scope 3, not Scope 2. Our post on transmission and distribution losses explains them, and well-to-tank emissions covers the fuel supply chain behind the grid. The UK electricity factor page has the same figures with a calculator.
The annual factor and the live grid
The DESNZ factor is a yearly average for reporting. The grid's carbon intensity also changes hour by hour with the wind, the sun and demand. For reports, use the annual factor: it is what SECR, PPN 006 and the GHG Protocol's location-based method expect. For running the business, the live figure tells you when to charge vans or run heavy equipment.
How Carbon Recycling helps
Carbon Recycling applies the right year's DESNZ factor to each entry automatically, from 2002 to 2026, and shows the factor's ID, year and value on every line, so you can see whether a figure moved because of your use or the grid. The "UK grid now" page in the app shows live carbon intensity from the NESO Carbon Intensity API, including the cleanest three-hour window in the next 48 hours and the figure for your sites' regions, so you can move flexible loads such as EV charging into greener hours. To check your own bills against both years' factors, try the free kWh to CO2e calculator.