What the losses are
تُفقد بعض الكهرباء على شكل حرارة في الكابلات والمحولات بين محطة الكهرباء وعدّادكم. وتقدّر ورقة منهجية DESNZ فاقد الشبكة في المملكة المتحدة بنحو 9% من الكهرباء المورّدة في البيانات التي تستند إليها معاملات 2026. وكان على محطات الكهرباء توليد تلك الكهرباء المفقودة، والانبعاثات الناتجة عن توليدها هي ما يقيسه معامل «فاقد النقل والتوزيع».
The government publishes the two parts separately. The main UK electricity factor covers electricity supplied to the grid, "not including the emissions associated with the transmission and distribution of electricity", and a second factor covers the losses. Added together, they give the emissions per kWh actually delivered to your building.
النطاق 2 أم النطاق 3؟
The GHG Protocol settles it. Its Corporate Standard says emissions from electricity lost in transmission and distribution are reported in Scope 2 by the company that owns or controls the T&D operation, and that end consumers don't report them in Scope 2 because they don't own or control the grid. Its Scope 3 Standard then lists "T&D losses, reported by end user" as part of category 3, fuel- and energy-related activities.
لذا بالنسبة إلى شركة تشتري الكهرباء:
- النطاق 2: kWh لديكم × 0.13096 (معامل الشبكة الكهربائية لعام 2026)
- النطاق 3، الفئة 3: kWh نفسها × 0.01299 (معامل فاقد النقل والتوزيع)
تضم الفئة 3 أيضًا انبعاثات «من البئر إلى الخزان» للوقود المستخدم في توليد الكهرباء لديكم، لذا كثيرًا ما يظهر الاثنان معًا.
مثال عملي
يستهلك مكتب 30,000 kWh من الكهرباء في 2026:
- النطاق 2: 30,000 × 0.13096 = 3.93 طن CO2e
- النطاق 3، فاقد النقل والتوزيع: 30,000 × 0.01299 = 0.39 طن CO2e
لا تضيفوا رقم فاقد النقل والتوزيع إلى النطاق 2. إذا طلب مشترٍ أو استبيان النطاق 2، فقدّموا 3.93 طن، واعرضوا الفاقد ضمن النطاق 3.
The factor year by year
| مجموعة المعاملات | كهرباء الشبكة (النطاق 2)، kg لكل kWh | T&D losses (Scope 3), kg per kWh | الفاقد الضمني |
|---|---|---|---|
| 2002 | 0.44914 | 0.04111 | 8.4% |
| 2003 | 0.47034 | 0.04404 | 8.6% |
| 2004 | 0.4567 | 0.04109 | 8.3% |
| 2005 | 0.47853 | 0.04427 | 8.5% |
| 2006 | 0.47337 | 0.04516 | 8.7% |
| 2007 | 0.46673 | 0.03646 | 7.2% |
| 2008 | 0.49608 | 0.03857 | 7.2% |
| 2009 | 0.49381 | 0.0391 | 7.3% |
| 2010 | 0.48531 | 0.03908 | 7.5% |
| 2011 | 0.45205 | 0.03863 | 7.9% |
| 2012 | 0.46002 | 0.03634 | 7.3% |
| 2013 | 0.44548 | 0.03809 | 7.9% |
| 2014 | 0.49426 | 0.04322 | 8.0% |
| 2015 | 0.46219 | 0.03816 | 7.6% |
| 2016 | 0.41205 | 0.03727 | 8.3% |
| 2017 | 0.35156 | 0.03287 | 8.6% |
| 2018 | 0.28307 | 0.02413 | 7.9% |
| 2019 | 0.2556 | 0.0217 | 7.8% |
| 2020 | 0.23314 | 0.02005 | 7.9% |
| 2021 | 0.21233 | 0.01879 | 8.1% |
| 2022 | 0.19338 | 0.01769 | 8.4% |
| 2023 | 0.20707 | 0.01792 | 8.0% |
| 2024 | 0.20705 | 0.0183 | 8.1% |
| 2025 | 0.177 | 0.01853 | 9.5% |
| 2026 | 0.13096 | 0.01299 | 9.0% |
The losses factor falls with the grid factor, because lost electricity is generated the same way as the rest. The share lost moves around from year to year. Our post on why the UK grid gets cleaner every year explains the main factor, and the UK electricity factor page lists both for every year.
Things that trip people up
- احتساب الفاقد في النطاق 2. فهذا يضخم النطاق 2 ويصعّب مقارنتكم بالشركات الأخرى. أبقوه في النطاق 3.
- تطبيقها على التوليد في الموقع. الألواح الشمسية التي تغذي مبناكم ليس لها فاقد في الشبكة. يشرح مقالنا عن الطاقة الشمسية على الأسطح والنطاق 2 كيفية التعامل معها.
- إغفال شبكات التدفئة. للتدفئة المركزية فاقد توزيع أيضًا. وتتضمن مجموعة الحكومة معاملًا له: في 2026، 0.00945 kg CO2e لكل kWh من الحرارة المشتراة.
- التبديل بين الإدراج والاستبعاد من سنة لأخرى. قرروا ما إذا كنتم ستدرجون الفئة 3، واذكروا ذلك في ملاحظة المنهجية والتزموا به.
How Carbon Recycling helps
تُدرج Carbon Recycling فاقد الشبكة البريطانية بإعداد واحد. فعند تفعيله، يحصل كل إدخال كهرباء، وكل مركبة كهربائية تُشحن من الشبكة، وكل إدخال تدفئة مركزية، على سطر T&D منفصل من المجموعة الحكومية للسنة نفسها، يُصنَّف في النطاق 3 الفئة 3 ولا يُخلط أبدًا بالنطاق 2. وبالنسبة إلى المواقع خارج المملكة المتحدة، يُستبعد الفاقد، لأنه لا يوجد مصدر مجاني ينشره لكل دولة. جرّبوا رقمكم أولًا في حاسبة kWh إلى CO2e المجانية بتحديد خانة النطاق 3.