What the losses are
Some electricity is lost as heat in cables and transformers between the power station and your meter. The DESNZ methodology paper puts UK grid losses at about 9% of the electricity supplied in the data behind the 2026 factors. Power stations had to generate that lost electricity, and the emissions from generating it are what the "T&D losses" factor measures.
The government publishes the two parts separately. The main UK electricity factor covers electricity supplied to the grid, "not including the emissions associated with the transmission and distribution of electricity", and a second factor covers the losses. Added together, they give the emissions per kWh actually delivered to your building.
Ulatus 2 või ulatus 3?
The GHG Protocol settles it. Its Corporate Standard says emissions from electricity lost in transmission and distribution are reported in Scope 2 by the company that owns or controls the T&D operation, and that end consumers don't report them in Scope 2 because they don't own or control the grid. Its Scope 3 Standard then lists "T&D losses, reported by end user" as part of category 3, fuel- and energy-related activities.
So for a business buying electricity:
- Ulatus 2: teie kWh × 0,13096 (aasta 2026 elektrivõrgu heitetegur)
- Ulatus 3, kategooria 3: samad kWh × 0,01299 (ülekande- ja jaotusvõrgu kadude tegur)
Kategooria 3 hõlmab ka teie elektri tootmiseks kasutatud kütuste eelahela heidet (well-to-tank), seega esinevad need kaks sageli koos.
Arvutusnäide
Kontor kasutab aastal 2026 30 000 kWh elektrit:
- Ulatus 2: 30 000 × 0,13096 = 3,93 tonni CO2e
- Ulatus 3, ülekande- ja jaotusvõrgu kaod: 30 000 × 0,01299 = 0,39 tonni CO2e
Ärge lisage ülekande- ja jaotusvõrgu kadude näitajat ulatusele 2. Kui ostja või küsimustik küsib ulatust 2, esitage 3,93 tonni ja näidake kadusid ulatuse 3 all.
The factor year by year
| Tegurite komplekt | Võrguelekter (ulatus 2), kg kWh kohta | T&D losses (Scope 3), kg per kWh | Kaudsed kaod |
|---|---|---|---|
| 2002 | 0.44914 | 0.04111 | 8.4% |
| 2003 | 0.47034 | 0.04404 | 8.6% |
| 2004 | 0.4567 | 0.04109 | 8.3% |
| 2005 | 0.47853 | 0.04427 | 8.5% |
| 2006 | 0.47337 | 0.04516 | 8.7% |
| 2007 | 0.46673 | 0.03646 | 7.2% |
| 2008 | 0.49608 | 0.03857 | 7.2% |
| 2009 | 0.49381 | 0.0391 | 7.3% |
| 2010 | 0.48531 | 0.03908 | 7.5% |
| 2011 | 0.45205 | 0.03863 | 7.9% |
| 2012 | 0.46002 | 0.03634 | 7.3% |
| 2013 | 0.44548 | 0.03809 | 7.9% |
| 2014 | 0.49426 | 0.04322 | 8.0% |
| 2015 | 0.46219 | 0.03816 | 7.6% |
| 2016 | 0.41205 | 0.03727 | 8.3% |
| 2017 | 0.35156 | 0.03287 | 8.6% |
| 2018 | 0.28307 | 0.02413 | 7.9% |
| 2019 | 0.2556 | 0.0217 | 7.8% |
| 2020 | 0.23314 | 0.02005 | 7.9% |
| 2021 | 0.21233 | 0.01879 | 8.1% |
| 2022 | 0.19338 | 0.01769 | 8.4% |
| 2023 | 0.20707 | 0.01792 | 8.0% |
| 2024 | 0.20705 | 0.0183 | 8.1% |
| 2025 | 0.177 | 0.01853 | 9.5% |
| 2026 | 0.13096 | 0.01299 | 9.0% |
The losses factor falls with the grid factor, because lost electricity is generated the same way as the rest. The share lost moves around from year to year. Our post on why the UK grid gets cleaner every year explains the main factor, and the UK electricity factor page lists both for every year.
Things that trip people up
- Kadude arvestamine ulatusse 2. See paisutab ulatust 2 ja muudab teid teiste ettevõtetega raskesti võrreldavaks. Hoidke neid ulatuses 3.
- Nende rakendamine kohapealsele tootmisele. Teie enda hoonet toitvatel päikesepaneelidel ei ole võrgukadusid. Meie postitus katusepäikesepaneelidest ja ulatusest 2 selgitab, kuidas seda käsitleda.
- Kaugküttevõrkude unustamine. Ka kaugküttel on jaotuskaod. Valitsuse komplektis on nende jaoks tegur: aastal 2026 0,00945 kg CO2e ostetud soojuse kWh kohta.
- Aastate vahel sisse- ja väljalülitamine. Otsustage, kas arvate kategooria 3 sisse, öelge seda oma metoodika märkuses ja pidage sellest kinni.
How Carbon Recycling helps
Carbon Recycling kaasab Ühendkuningriigi võrgukaod ühe seadistusega. Kui see on sisse lülitatud, saab iga elektrikanne, iga võrgust laetud elektrisõiduk ja iga kaugkütte kanne eraldi ülekande- ja jaotuskadude rea sama aasta valitsuse komplektist, mis kantakse ulatuse 3 kategooriasse 3 ega segune kunagi ulatusega 2. Väljaspool Ühendkuningriiki asuvate tegevuskohtade puhul jäetakse kaod välja, sest ükski tasuta allikas ei avalda neid kõigi riikide kohta. Proovige esmalt oma näitajat tasuta kWh-st CO2e-ks kalkulaatoris, märkides ulatuse 3 ruudu.