What the losses are

Some electricity is lost as heat in cables and transformers between the power station and your meter. The DESNZ methodology paper puts UK grid losses at about 9% of the electricity supplied in the data behind the 2026 factors. Power stations had to generate that lost electricity, and the emissions from generating it are what the "T&D losses" factor measures.

The government publishes the two parts separately. The main UK electricity factor covers electricity supplied to the grid, "not including the emissions associated with the transmission and distribution of electricity", and a second factor covers the losses. Added together, they give the emissions per kWh actually delivered to your building.

Scope 2 or Scope 3?

The GHG Protocol settles it. Its Corporate Standard says emissions from electricity lost in transmission and distribution are reported in Scope 2 by the company that owns or controls the T&D operation, and that end consumers don't report them in Scope 2 because they don't own or control the grid. Its Scope 3 Standard then lists "T&D losses, reported by end user" as part of category 3, fuel- and energy-related activities.

So for a business buying electricity:

  • 2. tvērums: jūsu kWh × 0,13096 (2026. gada elektrotīkla faktors)
  • 3. tvērums, 3. kategorija: tās pašas kWh × 0,01299 (pārvades un sadales zudumu faktors)

3. kategorijā ietilpst arī jūsu elektroenerģijas ražošanā izmantotās degvielas emisijas no ieguves līdz tvertnei, tāpēc abas bieži parādās kopā.

Aprēķina piemērs

Birojs 2026. gadā patērē 30 000 kWh elektroenerģijas:

  • Scope 2: 30,000 × 0.13096 = 3,93 tonnas CO2e
  • Scope 3, T&D losses: 30,000 × 0.01299 = 0,39 tonnas CO2e

Nepievienojiet pārvades un sadales zudumus 2. tvērumam. Ja pircējs vai anketa prasa 2. tvērumu, norādiet 3,93 tonnas un zudumus parādiet 3. tvērumā.

The factor year by year

Faktoru kopaTīkla elektroenerģija (2. tvērums), kg uz kWhT&D losses (Scope 3), kg per kWhNetiešie zudumi
20020.449140.041118.4%
20030.470340.044048.6%
20040.45670.041098.3%
20050.478530.044278.5%
20060.473370.045168.7%
20070.466730.036467.2%
20080.496080.038577.2%
20090.493810.03917.3%
20100.485310.039087.5%
20110.452050.038637.9%
20120.460020.036347.3%
20130.445480.038097.9%
20140.494260.043228.0%
20150.462190.038167.6%
20160.412050.037278.3%
20170.351560.032878.6%
20180.283070.024137.9%
20190.25560.02177.8%
20200.233140.020057.9%
20210.212330.018798.1%
20220.193380.017698.4%
20230.207070.017928.0%
20240.207050.01838.1%
20250.1770.018539.5%
20260.130960.012999.0%

The losses factor falls with the grid factor, because lost electricity is generated the same way as the rest. The share lost moves around from year to year. Our post on why the UK grid gets cleaner every year explains the main factor, and the UK electricity factor page lists both for every year.

Things that trip people up

  1. Zudumu uzskaitīšana 2. tvērumā. Tas palielina 2. tvērumu un apgrūtina salīdzināšanu ar citiem uzņēmumiem. Uzskaitiet tos 3. tvērumā.
  2. To piemērošana pašu ražotajai enerģijai. Saules paneļiem, kas apgādā jūsu ēku, nav tīkla zudumu. Mūsu rakstā par saules paneļiem uz jumta un 2. tvērumu ir paskaidrots, kā to uzskaitīt.
  3. Aizmirsti siltumapgādes tīkli. Arī centralizētajai siltumapgādei ir sadales zudumi. Valdības kopā ir faktors arī tiem: 2026. gadā 0,00945 kg CO2e par katru iegādāto siltuma kWh.
  4. Iekļaušana un neiekļaušana dažādos gados. Izlemiet, vai iekļaujat 3. kategoriju, norādiet to metodes piezīmē un pieturieties pie tā.

How Carbon Recycling helps

Carbon Recycling ietver Apvienotās Karalistes tīkla zudumus ar vienu iestatījumu. Kad tas ir ieslēgts, katrs elektroenerģijas ieraksts, katrs no tīkla uzlādēts elektrotransportlīdzeklis un katrs centralizētās siltumapgādes ieraksts saņem atsevišķu pārvades un sadales rindu no tā paša gada valdības kopas, kas iekļauta 3. tvēruma 3. kategorijā un nekad netiek sajaukta ar 2. tvērumu. Objektiem ārpus Apvienotās Karalistes zudumi netiek iekļauti, jo neviens bezmaksas avots tos nepublicē par katru valsti. Izmēģiniet savu skaitli bezmaksas kWh uz CO2e kalkulatorā, atzīmējot 3. tvēruma izvēles rūtiņu.