What the losses are
Some electricity is lost as heat in cables and transformers between the power station and your meter. The DESNZ methodology paper puts UK grid losses at about 9% of the electricity supplied in the data behind the 2026 factors. Power stations had to generate that lost electricity, and the emissions from generating it are what the "T&D losses" factor measures.
The government publishes the two parts separately. The main UK electricity factor covers electricity supplied to the grid, "not including the emissions associated with the transmission and distribution of electricity", and a second factor covers the losses. Added together, they give the emissions per kWh actually delivered to your building.
Scope 2 or Scope 3?
The GHG Protocol settles it. Its Corporate Standard says emissions from electricity lost in transmission and distribution are reported in Scope 2 by the company that owns or controls the T&D operation, and that end consumers don't report them in Scope 2 because they don't own or control the grid. Its Scope 3 Standard then lists "T&D losses, reported by end user" as part of category 3, fuel- and energy-related activities.
So for a business buying electricity:
- 2. hatókör: az Ön kWh-ja × 0,13096 (a(z) 2026. évi hálózati tényező)
- 3. hatókör, 3. kategória: ugyanazon kWh × 0,01299 (az átviteli és elosztási veszteségek tényezője)
A(z) 3. kategória a villamos energia mögötti tüzelőanyagok kitermeléstől a tartályig (well-to-tank) számított kibocsátását is tartalmazza, ezért a kettő gyakran együtt jelenik meg.
Kidolgozott példa
Egy iroda 2026-ben 30 000 kWh villamos energiát használ fel:
- Scope 2: 30,000 × 0.13096 = 3,93 tonna CO2e
- Scope 3, T&D losses: 30,000 × 0.01299 = 0,39 tonna CO2e
Ne adja hozzá a hálózati veszteség értékét a(z) 2. hatókörhöz. Ha egy ajánlatkérő vagy kérdőív a(z) 2. hatókört kéri, 3,93 tonnát adjon meg, a veszteségeket pedig a(z) 3. hatókörben mutassa ki.
The factor year by year
| Tényezőkészlet | Hálózati villamos energia (2. hatókör), kg/kWh | T&D losses (Scope 3), kg per kWh | Számított veszteség |
|---|---|---|---|
| 2002 | 0.44914 | 0.04111 | 8.4% |
| 2003 | 0.47034 | 0.04404 | 8.6% |
| 2004 | 0.4567 | 0.04109 | 8.3% |
| 2005 | 0.47853 | 0.04427 | 8.5% |
| 2006 | 0.47337 | 0.04516 | 8.7% |
| 2007 | 0.46673 | 0.03646 | 7.2% |
| 2008 | 0.49608 | 0.03857 | 7.2% |
| 2009 | 0.49381 | 0.0391 | 7.3% |
| 2010 | 0.48531 | 0.03908 | 7.5% |
| 2011 | 0.45205 | 0.03863 | 7.9% |
| 2012 | 0.46002 | 0.03634 | 7.3% |
| 2013 | 0.44548 | 0.03809 | 7.9% |
| 2014 | 0.49426 | 0.04322 | 8.0% |
| 2015 | 0.46219 | 0.03816 | 7.6% |
| 2016 | 0.41205 | 0.03727 | 8.3% |
| 2017 | 0.35156 | 0.03287 | 8.6% |
| 2018 | 0.28307 | 0.02413 | 7.9% |
| 2019 | 0.2556 | 0.0217 | 7.8% |
| 2020 | 0.23314 | 0.02005 | 7.9% |
| 2021 | 0.21233 | 0.01879 | 8.1% |
| 2022 | 0.19338 | 0.01769 | 8.4% |
| 2023 | 0.20707 | 0.01792 | 8.0% |
| 2024 | 0.20705 | 0.0183 | 8.1% |
| 2025 | 0.177 | 0.01853 | 9.5% |
| 2026 | 0.13096 | 0.01299 | 9.0% |
The losses factor falls with the grid factor, because lost electricity is generated the same way as the rest. The share lost moves around from year to year. Our post on why the UK grid gets cleaner every year explains the main factor, and the UK electricity factor page lists both for every year.
Things that trip people up
- A veszteségek elszámolása a(z) 2. hatókörben. Ez felfelé torzítja a(z) 2. hatókört, és megnehezíti az összehasonlítást más cégekkel. Tartsa őket a(z) 3. hatókörben.
- Alkalmazása a helyszíni termelésre. A saját épületét ellátó napelemeknek nincs hálózati vesztesége. A tetőre szerelt napelemekről és a 2. hatókörről szóló bejegyzésünk leírja, hogyan kezelje.
- A hőhálózatok elfelejtése. A távhőnek is vannak elosztási veszteségei. A kormányzati készlet tartalmaz rájuk tényezőt: 2026-ban 0,00945 kg CO2e vásárolt hő kWh-nként.
- Ki-be kapcsolgatás évek között. Döntse el, belefoglalja-e a(z) 3. kategóriát, írja le a módszertani megjegyzésben, és tartson ki mellette.
How Carbon Recycling helps
A Carbon Recycling egyetlen beállítással figyelembe veszi a brit hálózati veszteségeket. Bekapcsolt állapotban minden villamosenergia-tétel, minden hálózatról töltött elektromos jármű és minden távhőtétel külön T&D-sort kap ugyanazon évi kormányzati készletből, a 3. hatókör 3. kategóriájában, soha nem keverve a 2. hatókörbe. Az Egyesült Királyságon kívüli telephelyeknél a veszteségek kimaradnak, mert nincs olyan ingyenes forrás, amely minden országra közzétenné őket. Próbálja ki saját értékével az ingyenes kWh–CO2e kalkulátorban a 3. hatókör jelölőnégyzet bejelölésével.