What the losses are

Some electricity is lost as heat in cables and transformers between the power station and your meter. The DESNZ methodology paper puts UK grid losses at about 9% of the electricity supplied in the data behind the 2026 factors. Power stations had to generate that lost electricity, and the emissions from generating it are what the "T&D losses" factor measures.

The government publishes the two parts separately. The main UK electricity factor covers electricity supplied to the grid, "not including the emissions associated with the transmission and distribution of electricity", and a second factor covers the losses. Added together, they give the emissions per kWh actually delivered to your building.

Scope 2 or Scope 3?

The GHG Protocol settles it. Its Corporate Standard says emissions from electricity lost in transmission and distribution are reported in Scope 2 by the company that owns or controls the T&D operation, and that end consumers don't report them in Scope 2 because they don't own or control the grid. Its Scope 3 Standard then lists "T&D losses, reported by end user" as part of category 3, fuel- and energy-related activities.

So for a business buying electricity:

  • Πεδίο 2: οι kWh σας × 0,13096 (ο συντελεστής δικτύου του 2026)
  • Πεδίο 3, κατηγορία 3: οι ίδιες kWh × 0,01299 (ο συντελεστής απωλειών μεταφοράς και διανομής)

Η κατηγορία 3 περιλαμβάνει επίσης τις εκπομπές από την εξόρυξη έως τη δεξαμενή (well-to-tank) των καυσίμων πίσω από την ηλεκτρική ενέργειά σας, οπότε οι δύο εμφανίζονται συχνά μαζί.

Παράδειγμα υπολογισμού

Ένα γραφείο καταναλώνει 30.000 kWh ηλεκτρικής ενέργειας το 2026:

  • Scope 2: 30,000 × 0.13096 = 3,93 τόνοι CO2e
  • Scope 3, T&D losses: 30,000 × 0.01299 = 0,39 τόνοι CO2e

Μην προσθέτετε το στοιχείο των απωλειών T&D στο Πεδίο 2. Αν ένας αγοραστής ή ένα ερωτηματολόγιο ζητά το Πεδίο 2, δώστε 3,93 τόνους και εμφανίστε τις απώλειες στο Πεδίο 3.

The factor year by year

Σύνολο συντελεστώνΗλεκτρισμός δικτύου (Πεδίο 2), kg ανά kWhT&D losses (Scope 3), kg per kWhΤεκμαιρόμενες απώλειες
20020.449140.041118.4%
20030.470340.044048.6%
20040.45670.041098.3%
20050.478530.044278.5%
20060.473370.045168.7%
20070.466730.036467.2%
20080.496080.038577.2%
20090.493810.03917.3%
20100.485310.039087.5%
20110.452050.038637.9%
20120.460020.036347.3%
20130.445480.038097.9%
20140.494260.043228.0%
20150.462190.038167.6%
20160.412050.037278.3%
20170.351560.032878.6%
20180.283070.024137.9%
20190.25560.02177.8%
20200.233140.020057.9%
20210.212330.018798.1%
20220.193380.017698.4%
20230.207070.017928.0%
20240.207050.01838.1%
20250.1770.018539.5%
20260.130960.012999.0%

The losses factor falls with the grid factor, because lost electricity is generated the same way as the rest. The share lost moves around from year to year. Our post on why the UK grid gets cleaner every year explains the main factor, and the UK electricity factor page lists both for every year.

Things that trip people up

  1. Καταχώριση των απωλειών στο Πεδίο 2. Διογκώνει το Πεδίο 2 και δυσκολεύει τη σύγκρισή σας με άλλες εταιρείες. Κρατήστε τις στο Πεδίο 3.
  2. Εφαρμογή τους στην επιτόπια παραγωγή. Τα φωτοβολταϊκά που τροφοδοτούν το δικό σας κτίριο δεν έχουν απώλειες δικτύου. Το άρθρο μας για τα φωτοβολταϊκά στέγης και το Πεδίο 2 εξηγεί πώς να τα αντιμετωπίσετε.
  3. Παράλειψη των δικτύων θερμότητας. Η τηλεθέρμανση έχει επίσης απώλειες διανομής. Το κυβερνητικό σύνολο περιλαμβάνει συντελεστή γι' αυτές: το 2026, 0,00945 kg CO2e ανά kWh αγορασμένης θερμότητας.
  4. Συμπερίληψη και εξαίρεση εναλλάξ από χρόνο σε χρόνο. Αποφασίστε αν θα συμπεριλάβετε την κατηγορία 3, αναφέρετέ το στο σημείωμα μεθοδολογίας και τηρήστε το.

How Carbon Recycling helps

Το Carbon Recycling περιλαμβάνει τις απώλειες του δικτύου του Ηνωμένου Βασιλείου με μία μόνο ρύθμιση. Όταν είναι ενεργοποιημένη, κάθε καταχώριση ηλεκτρικής ενέργειας, κάθε ηλεκτρικό όχημα που φορτίζεται από το δίκτυο και κάθε καταχώριση τηλεθέρμανσης λαμβάνει χωριστή γραμμή απωλειών μεταφοράς και διανομής (T&D) από το κυβερνητικό σύνολο του ίδιου έτους, καταχωρισμένη στο Πεδίο 3, κατηγορία 3, και ποτέ αναμεμειγμένη με το Πεδίο 2. Για εγκαταστάσεις εκτός Ηνωμένου Βασιλείου, οι απώλειες δεν περιλαμβάνονται, επειδή καμία δωρεάν πηγή δεν τις δημοσιεύει για κάθε χώρα. Δοκιμάστε πρώτα το δικό σας στοιχείο στον δωρεάν υπολογιστή kWh σε CO2e επιλέγοντας το πλαίσιο του Πεδίου 3.