What the losses are
Some electricity is lost as heat in cables and transformers between the power station and your meter. The DESNZ methodology paper puts UK grid losses at about 9% of the electricity supplied in the data behind the 2026 factors. Power stations had to generate that lost electricity, and the emissions from generating it are what the "T&D losses" factor measures.
The government publishes the two parts separately. The main UK electricity factor covers electricity supplied to the grid, "not including the emissions associated with the transmission and distribution of electricity", and a second factor covers the losses. Added together, they give the emissions per kWh actually delivered to your building.
Scope 2 or Scope 3?
The GHG Protocol settles it. Its Corporate Standard says emissions from electricity lost in transmission and distribution are reported in Scope 2 by the company that owns or controls the T&D operation, and that end consumers don't report them in Scope 2 because they don't own or control the grid. Its Scope 3 Standard then lists "T&D losses, reported by end user" as part of category 3, fuel- and energy-related activities.
So for a business buying electricity:
- Scope 2: kWh:si × 0,13096 (vuoden 2026 sähköverkon kerroin)
- Scope 3, luokka 3: samat kWh × 0,01299 (siirto- ja jakeluhäviöiden kerroin)
Luokkaan 3 kuuluvat myös sähkösi tuotannossa käytettyjen polttoaineiden well-to-tank-päästöt, joten nämä kaksi esiintyvät usein yhdessä.
Laskuesimerkki
Toimisto käyttää 30 000 kWh sähköä vuonna 2026:
- Scope 2: 30,000 × 0.13096 = 3,93 tonnia CO2e
- Scope 3, T&D losses: 30,000 × 0.01299 = 0,39 tonnia CO2e
Älä lisää siirto- ja jakeluhäviöitä Scope 2 -lukuun. Jos ostaja tai kysely pyytää Scope 2 -päästöjä, ilmoita 3,93 tonnia ja esitä häviöt Scope 3 -päästöissä.
The factor year by year
| Kerroinsarja | Verkkosähkö (Scope 2), kg/kWh | T&D losses (Scope 3), kg per kWh | Laskennalliset häviöt |
|---|---|---|---|
| 2002 | 0.44914 | 0.04111 | 8.4% |
| 2003 | 0.47034 | 0.04404 | 8.6% |
| 2004 | 0.4567 | 0.04109 | 8.3% |
| 2005 | 0.47853 | 0.04427 | 8.5% |
| 2006 | 0.47337 | 0.04516 | 8.7% |
| 2007 | 0.46673 | 0.03646 | 7.2% |
| 2008 | 0.49608 | 0.03857 | 7.2% |
| 2009 | 0.49381 | 0.0391 | 7.3% |
| 2010 | 0.48531 | 0.03908 | 7.5% |
| 2011 | 0.45205 | 0.03863 | 7.9% |
| 2012 | 0.46002 | 0.03634 | 7.3% |
| 2013 | 0.44548 | 0.03809 | 7.9% |
| 2014 | 0.49426 | 0.04322 | 8.0% |
| 2015 | 0.46219 | 0.03816 | 7.6% |
| 2016 | 0.41205 | 0.03727 | 8.3% |
| 2017 | 0.35156 | 0.03287 | 8.6% |
| 2018 | 0.28307 | 0.02413 | 7.9% |
| 2019 | 0.2556 | 0.0217 | 7.8% |
| 2020 | 0.23314 | 0.02005 | 7.9% |
| 2021 | 0.21233 | 0.01879 | 8.1% |
| 2022 | 0.19338 | 0.01769 | 8.4% |
| 2023 | 0.20707 | 0.01792 | 8.0% |
| 2024 | 0.20705 | 0.0183 | 8.1% |
| 2025 | 0.177 | 0.01853 | 9.5% |
| 2026 | 0.13096 | 0.01299 | 9.0% |
The losses factor falls with the grid factor, because lost electricity is generated the same way as the rest. The share lost moves around from year to year. Our post on why the UK grid gets cleaner every year explains the main factor, and the UK electricity factor page lists both for every year.
Things that trip people up
- Siirtohäviöiden laskeminen Scope 2 -päästöihin. Se paisuttaa Scope 2 -päästöjä ja vaikeuttaa vertailua muihin yrityksiin. Pidä ne Scope 3 -päästöissä.
- Niiden soveltaminen omaan tuotantoon. Omaa rakennusta syöttävillä aurinkopaneeleilla ei ole verkkohäviöitä. Kirjoituksemme katon aurinkosähköstä ja Scope 2:stä kertoo, miten sitä käsitellään.
- Lämpöverkkojen unohtaminen. Kaukolämmöllä on myös jakeluhäviöitä. Hallituksen kerroinsarjassa on niille kerroin: vuonna 2026 0,00945 kg CO2e ostettua lämpö-kWh:ta kohden.
- Vuorottelu mukaan ottamisen ja pois jättämisen välillä. Päätä, sisällytätkö luokan 3, kerro se menetelmäkuvauksessa ja pysy päätöksessä.
How Carbon Recycling helps
Carbon Recycling sisällyttää Iso-Britannian sähköverkon häviöt yhdellä asetuksella. Kun se on käytössä, jokainen sähkömerkintä, jokainen verkosta ladattu sähköajoneuvo ja jokainen kaukolämpömerkintä saa erillisen siirto- ja jakeluhäviörivin saman vuoden hallituksen sarjasta, kirjattuna Scope 3 -luokkaan 3 eikä koskaan sekoitettuna Scope 2 -päästöihin. Iso-Britannian ulkopuolisten toimipaikkojen häviöt jätetään pois, koska mikään ilmainen lähde ei julkaise niitä kaikille maille. Kokeile ensin omaa lukuasi ilmaisella kWh–CO2e-laskurilla valitsemalla Scope 3 -ruutu.