What the losses are
Some electricity is lost as heat in cables and transformers between the power station and your meter. The DESNZ methodology paper puts UK grid losses at about 9% of the electricity supplied in the data behind the 2026 factors. Power stations had to generate that lost electricity, and the emissions from generating it are what the "T&D losses" factor measures.
The government publishes the two parts separately. The main UK electricity factor covers electricity supplied to the grid, "not including the emissions associated with the transmission and distribution of electricity", and a second factor covers the losses. Added together, they give the emissions per kWh actually delivered to your building.
Scope 2 or Scope 3?
The GHG Protocol settles it. Its Corporate Standard says emissions from electricity lost in transmission and distribution are reported in Scope 2 by the company that owns or controls the T&D operation, and that end consumers don't report them in Scope 2 because they don't own or control the grid. Its Scope 3 Standard then lists "T&D losses, reported by end user" as part of category 3, fuel- and energy-related activities.
So for a business buying electricity:
- Umfang 2: kWh × 0.13096 (stuðull raforkukerfisins fyrir 2026)
- Umfang 3, flokkur 3: sömu kWh × 0.01299 (stuðullinn fyrir flutnings- og dreifitöp)
Í flokki 3 er einnig losun við vinnslu og flutning eldsneytis (well-to-tank) að baki raforkunni þinni, svo þetta tvennt birtist oft saman.
Útreiknað dæmi
Skrifstofa notar 30,000 kWh af rafmagni árið 2026:
- Scope 2: 30,000 × 0.13096 = 3.93 tonn CO2e
- Scope 3, T&D losses: 30,000 × 0.01299 = 0.39 tonn CO2e
Ekki bæta T&D-tölunni við umfang 2. Ef kaupandi eða spurningalisti biður um umfang 2 skaltu gefa upp 3.93 tonn og sýna töpin undir umfangi 3.
The factor year by year
| Stuðlasafn | Rafmagn frá raforkukerfinu (umfang 2), kg á kWh | T&D losses (Scope 3), kg per kWh | Áætluð töp |
|---|---|---|---|
| 2002 | 0.44914 | 0.04111 | 8.4% |
| 2003 | 0.47034 | 0.04404 | 8.6% |
| 2004 | 0.4567 | 0.04109 | 8.3% |
| 2005 | 0.47853 | 0.04427 | 8.5% |
| 2006 | 0.47337 | 0.04516 | 8.7% |
| 2007 | 0.46673 | 0.03646 | 7.2% |
| 2008 | 0.49608 | 0.03857 | 7.2% |
| 2009 | 0.49381 | 0.0391 | 7.3% |
| 2010 | 0.48531 | 0.03908 | 7.5% |
| 2011 | 0.45205 | 0.03863 | 7.9% |
| 2012 | 0.46002 | 0.03634 | 7.3% |
| 2013 | 0.44548 | 0.03809 | 7.9% |
| 2014 | 0.49426 | 0.04322 | 8.0% |
| 2015 | 0.46219 | 0.03816 | 7.6% |
| 2016 | 0.41205 | 0.03727 | 8.3% |
| 2017 | 0.35156 | 0.03287 | 8.6% |
| 2018 | 0.28307 | 0.02413 | 7.9% |
| 2019 | 0.2556 | 0.0217 | 7.8% |
| 2020 | 0.23314 | 0.02005 | 7.9% |
| 2021 | 0.21233 | 0.01879 | 8.1% |
| 2022 | 0.19338 | 0.01769 | 8.4% |
| 2023 | 0.20707 | 0.01792 | 8.0% |
| 2024 | 0.20705 | 0.0183 | 8.1% |
| 2025 | 0.177 | 0.01853 | 9.5% |
| 2026 | 0.13096 | 0.01299 | 9.0% |
The losses factor falls with the grid factor, because lost electricity is generated the same way as the rest. The share lost moves around from year to year. Our post on why the UK grid gets cleaner every year explains the main factor, and the UK electricity factor page lists both for every year.
Things that trip people up
- Að telja töp í umfangi 2. Það blæs upp umfang 2 og gerir erfitt að bera þig saman við önnur fyrirtæki. Hafðu þau í umfangi 3.
- Að beita þeim á eigin framleiðslu. Sólarsellur sem knýja eigin byggingu hafa engin töp á raforkukerfinu. Færsla okkar um sólarsellur á þaki og umfang 2 fjallar um hvernig fara á með það.
- Að gleyma varmaveitum. Fjarvarmi hefur líka dreifitöp. Stuðlasafn stjórnvalda inniheldur stuðul fyrir þau: árið 2026, 0.00945 kg CO2e á hverja keypta kWh af varma.
- Að taka með og sleppa á víxl milli ára. Ákveddu hvort þú tekur flokk 3 með, taktu það fram í aðferðalýsingunni og haltu þig við það.
How Carbon Recycling helps
Carbon Recycling tekur flutnings- og dreifitöp í Bretlandi með einni stillingu. Þegar hún er virk fær hver raforkufærsla, hver rafbíll sem hlaðinn er af kerfinu og hver fjarvarmafærsla sérstaka T&D-línu úr stuðlasafni stjórnvalda sama árs, skráða í umfangi 3, flokki 3, og aldrei blandað við umfang 2. Fyrir starfsstöðvar utan Bretlands eru töp undanskilin, þar sem engin ókeypis heimild birtir þau fyrir öll lönd. Prófaðu þína eigin tölu fyrst í ókeypis reiknivélinni fyrir kWh í CO2e með því að haka í reitinn fyrir umfang 3.