What the losses are

Some electricity is lost as heat in cables and transformers between the power station and your meter. The DESNZ methodology paper puts UK grid losses at about 9% of the electricity supplied in the data behind the 2026 factors. Power stations had to generate that lost electricity, and the emissions from generating it are what the "T&D losses" factor measures.

The government publishes the two parts separately. The main UK electricity factor covers electricity supplied to the grid, "not including the emissions associated with the transmission and distribution of electricity", and a second factor covers the losses. Added together, they give the emissions per kWh actually delivered to your building.

Scope 2 or Scope 3?

The GHG Protocol settles it. Its Corporate Standard says emissions from electricity lost in transmission and distribution are reported in Scope 2 by the company that owns or controls the T&D operation, and that end consumers don't report them in Scope 2 because they don't own or control the grid. Its Scope 3 Standard then lists "T&D losses, reported by end user" as part of category 3, fuel- and energy-related activities.

So for a business buying electricity:

  • 2 apimtis: jūsų kWh × 0,13096 (2026 m. tinklo koeficientas)
  • 3 apimtis, 3 kategorija: tos pačios kWh × 0,01299 (perdavimo ir skirstymo nuostolių koeficientas)

3 kategorijai taip pat priskiriami jūsų elektrai pagaminti naudoto kuro „nuo gręžinio iki bako“ išmetimai, todėl abu dažnai pateikiami kartu.

Pavyzdys

Biuras 2026 m. suvartoja 30 000 kWh elektros:

  • Scope 2: 30,000 × 0.13096 = 3,93 t CO2e
  • Scope 3, T&D losses: 30,000 × 0.01299 = 0,39 t CO2e

Neįtraukite perdavimo ir skirstymo nuostolių į 2 apimtį. Jei pirkėjas ar klausimynas prašo 2 apimties, nurodykite 3,93 t, o nuostolius parodykite 3 apimtyje.

The factor year by year

Koeficientų rinkinysElektra iš tinklo (2 apimtis), kg kWhT&D losses (Scope 3), kg per kWhNumanomi nuostoliai
20020.449140.041118.4%
20030.470340.044048.6%
20040.45670.041098.3%
20050.478530.044278.5%
20060.473370.045168.7%
20070.466730.036467.2%
20080.496080.038577.2%
20090.493810.03917.3%
20100.485310.039087.5%
20110.452050.038637.9%
20120.460020.036347.3%
20130.445480.038097.9%
20140.494260.043228.0%
20150.462190.038167.6%
20160.412050.037278.3%
20170.351560.032878.6%
20180.283070.024137.9%
20190.25560.02177.8%
20200.233140.020057.9%
20210.212330.018798.1%
20220.193380.017698.4%
20230.207070.017928.0%
20240.207050.01838.1%
20250.1770.018539.5%
20260.130960.012999.0%

The losses factor falls with the grid factor, because lost electricity is generated the same way as the rest. The share lost moves around from year to year. Our post on why the UK grid gets cleaner every year explains the main factor, and the UK electricity factor page lists both for every year.

Things that trip people up

  1. Nuostolių priskyrimas 2 apimčiai. Tai padidina 2 apimtį ir apsunkina palyginimą su kitomis įmonėmis. Priskirkite juos 3 apimčiai.
  2. Taikyti juos vietinei gamybai. Saulės moduliai, tiekiantys elektrą jūsų pačių pastatui, tinklo nuostolių neturi. Kaip tai vertinti, aptariama mūsų įraše apie saulės modulius ant stogo ir 2 apimtį.
  3. Pamirštami šilumos tinklai. Centralizuotas šildymas taip pat turi skirstymo nuostolių. Vyriausybės rinkinyje yra jiems skirtas koeficientas: 2026 m. – 0,00945 kg CO2e už įsigytą šilumos kWh.
  4. Įtraukimas ir neįtraukimas skirtingais metais. Nuspręskite, ar įtraukiate 3 kategoriją, nurodykite tai metodikos pastaboje ir to laikykitės.

How Carbon Recycling helps

Carbon Recycling JK tinklo nuostolius įtraukia vienu nustatymu. Jį įjungus, kiekvienam elektros įrašui, kiekvienai iš tinklo įkraunamai elektrinei transporto priemonei ir kiekvienam centralizuoto šildymo įrašui sukuriama atskira perdavimo ir skirstymo nuostolių eilutė pagal tų pačių metų vyriausybės rinkinį, priskiriama 3 apimties 3 kategorijai ir niekada nemaišoma su 2 apimtimi. Objektams už JK ribų nuostoliai neįtraukiami, nes jokio nemokamo šaltinio, skelbiančio juos kiekvienai šaliai, nėra. Pirmiausia išbandykite savo skaičių nemokamoje kWh į CO2e skaičiuoklėje, pažymėję 3 apimties langelį.