What the rules say

The 2018 regulations that created SECR say the directors' report "must state at least one ratio which expresses the company's annual emissions in relation to a quantifiable factor associated with the company's activities". They don't say which. The government's Environmental Reporting Guidelines add that the ratio should be the one most relevant to your business, calculated on a consistent basis year on year, with the method disclosed.

The guidelines also list examples. For any sector: tonnes of CO2e per £m sales revenue and per full-time equivalent employee. By sector: per square metre of gross store area for retail, per square metre for property, per tonne of production for manufacturing, and per tonne kilometre for transport. DfE goes further for academy trusts and encourages tonnes per pupil, so trusts can be compared.

The three common choices

النسبةSuitsWatch out for
tCO2e per £m turnoverأي نشاط تجاري؛ سهلة المقارنة بين القطاعات؛ وتشير الإرشادات إلى أن النسب المالية تناسب المقارنة بين شركات ذات منتجات مختلفةتخفضها ارتفاعات الأسعار والتضخم دون أي تغيير حقيقي. وقد يؤدي عقد كبير لمرة واحدة إلى تأرجحها
tCO2e per employeeالمكاتب والاستشارات والوكالات وشركات الخدمات حيث يحدد الأشخاص البصمة الكربونيةUse full-time equivalents. Outsourcing work makes it look better without cutting anything
kgCO2e لكل m²الشركات التي تتكون بصمتها في الغالب من تدفئة المباني وتزويدها بالطاقة: العقارات، والتجزئة، والمدارسUse the same floor area measure each year. It says nothing about vehicles or travel

The guidelines also suggest activity ratios, such as per unit produced, when you compare with firms making similar products. If your business has very different activities, you can give a ratio for each.

مثال عملي: النمو يُخفي التقدم، والعكس

توظّف شركة ستة موظفين جدد وتزيد حجم أعمالها بنسبة 30%. ويرتفع استهلاكها من الغاز والكهرباء وديزل الشاحنات الصغيرة، لكن بدرجة أقل. ولعزل أثر تغيّر النشاط، تستخدم السنتان كلتاهما المعاملات الحكومية لعام 2026:

Year 1Year 2Change
النطاقان 1 و2، tCO2e23.3828.14+20%
tCO2e per £m turnover11.6910.82-7%
tCO2e per employee1.171.08-7%
kgCO2e لكل m² (600 m² في كلتا السنتين)39.046.9+20%

Total emissions rose 20%, while emissions per £m and per employee fell. Both statements are true, and a reader needs both. The floor area didn't change, so the per m² ratio moves exactly with the total. This is the trap the government's guidance warns about: an intensity target can be met while total emissions still go up.

The reverse happens too. If turnover falls in a bad year, emissions per £m can rise even when you used less energy. Explain both in the narrative, and if the factors changed between years, say how much of the change came from that. Our post on why footprints dropped in 2026 shows how.

اختيار ما يناسبكم

  1. اسألوا عمّا يحرّك انبعاثاتكم فعلًا: المباني أم الأشخاص أم المركبات أم الإنتاج.
  2. اختاروا نسبة يزداد مقامها عندما يزداد ذلك العامل المحرك.
  3. تحققوا من أنكم ستحصلون على رقم المقام كل عام من المصدر نفسه، مثل حجم الأعمال المدقق أو متوسط الموظفين بدوام كامل مكافئ.
  4. Write down the definition and keep it. If you must change ratio, give both for the year you switch and explain why.

ينبغي للمدارس وصناديق الأكاديميات قراءة الإبلاغ عن الكربون للمدارس، ولمقدمي خدمات الإسكان قراءة مقالنا عن المؤسسات الخيرية وجمعيات الإسكان، الذي يتناول الانبعاثات لكل مسكن.

How Carbon Recycling helps

يتيح تقرير SECR من Carbon Recycling ثلاث نسب كثافة: tCO2e لكل مليون جنيه إسترليني من حجم الأعمال، ولكل موظف بدوام كامل، وkgCO2e لكل m² من المساحة الأرضية. أدخلوا حجم الأعمال أو عدد الموظفين أو المساحة الأرضية لكل عام، فيعرض التقرير نسبة هذا العام بجانب نسبة العام الماضي، محسوبتين على الأساس نفسه، إلى جانب استهلاك الطاقة والانبعاثات والمنهجية. كما يحسب بنك إجابات استبيانات المورّدين المجاني الأرقام لكل موظف ولكل مليون جنيه إسترليني لسؤال الكثافة الذي يطرحه العملاء كثيرًا.